13 research outputs found

    Followup of a solid solitary pulmonary nodule with low metabolic activity

    Get PDF
    AbstractAn incidentally found solid solitary pulmonary nodule (SPN) was studied using FDG PET/CT. The SPN (at that time 11mm) showed only minimal FDG uptake, with a maximum standardized uptake value of 1.7 (max SUV). This suggested a benign lesion. When followup CT was performed six months later, the SPN had grown to 12mm. The patient was re-examined by FDG PET/CT five months later to exclude malignancy. The SPN was now FDG avid, and its size was 14mm. The max SUV was 12.7, consistent with a malignant disease. The patient underwent surgery, and histological examination demonstrated a solid adenocarcinoma (gradus III). The increase in glucose metabolism can be attributed to a change in the histopathologic subtype or molecular features of the SPN. The importance of a followup of nonmetabolically active SPNs is emphasized, primarily by CT (due to its convenience and low cost)

    Preservation of fatty acid signatures in three vertebrate species after six months of storage at various temperatures

    Get PDF
    Fatty acid (FA) signatures (FAS) are important tools to assess the foraging ecology of wild animals. The present study was conducted to assess how well the general FAS and the proportions of individual FA are preserved in fat samples stored at different temperatures (196, -80, -20, +4 and +20 degrees C). Using three species (laboratory rat, American mink and rainbow trout), FAS were determined immediately upon sampling. Thereafter, eight subsamples per storage temperature from the inner part of the sample unaffected by oxygen and light were re-analyzed after 1, 2, 3, 7, 28, 84 and 168 days. Each time the remaining sample was sealed in its vial after replacing air with nitrogen gas. The results were tested with the mixed model and discriminant analyses. Generally, the FAS were well preserved regardless of storage temperature, and only a few major FA showed significant changes even after the 6-month period at room temperature. After an initial first-day change in proportions, presumably due to post-mortem enzymatic activities, the remaining minor changes could not be clearly attributed to either further autolysis, decomposition or autoxidation. In the discriminant analysis, the species-specific differences dominated and remained distinct even after 6 months. Furthermore, the analysis mostly classified the samples preserved at sub- and above-freezing temperatures separate from each other, and the general deviation from the initial analysis results was present as early as after 1 day. If FAS are to be analyzed in a very precise manner, the analysis should be performed immediately upon sampling. However, FAS remain adequately reliable for long periods of time even without preservation in deep freeze, widening the availability of potential samples for studies on foraging ecology and related disciplines.Peer reviewe

    Adaptive Autoregressive Model for Reduction of Noise in SPECT

    Get PDF
    This paper presents improved autoregressive modelling (AR) to reduce noise in SPECT images. An AR filter was applied to prefilter projection images and postfilter ordered subset expectation maximisation (OSEM) reconstruction images (AR-OSEM-AR method). The performance of this method was compared with filtered back projection (FBP) preceded by Butterworth filtering (BW-FBP method) and the OSEM reconstruction method followed by Butterworth filtering (OSEM-BW method). A mathematical cylinder phantom was used for the study. It consisted of hot and cold objects. The tests were performed using three simulated SPECT datasets. Image quality was assessed by means of the percentage contrast resolution (CR%) and the full width at half maximum (FWHM) of the line spread functions of the cylinders. The BW-FBP method showed the highest CR% values and the AR-OSEM-AR method gave the lowest CR% values for cold stacks. In the analysis of hot stacks, the BW-FBP method had higher CR% values than the OSEM-BW method. The BW-FBP method exhibited the lowest FWHM values for cold stacks and the AR-OSEM-AR method for hot stacks. In conclusion, the AR-OSEM-AR method is a feasible way to remove noise from SPECT images. It has good spatial resolution for hot objects
    corecore